anti-static-epoxy-floor-paint--25kg-a21kg--b4kg-esd-floor-for-electronics--data-centres, anti-static-epoxy-floor-paint--25kg-a21kg--b4kg-esd-floor-for-electronics--data-centres, /floor-paint
Anti-static epoxy floor paint, 25kg set (A 21kg + B 4kg). Surface resistance 10⁶–10⁹ Ω — ESD compliant floor for electronics manufacturing, data centres, and precision instrument facilities. 16 colours. MOQ 1 ton. CE certified.
Many procurement teams begin an ESD floor paint comparison by lining up supplier quotes — and only discover months later that the real cost gap shows up in re-testing, re-coating, or compliance failures. Think of an anti-static floor coating like a resistor in a circuit: it has to slow electrostatic charge into a controlled, dissipative range. Get the resistance window wrong, and even an expensive coating becomes a liability.
This Anti-Static Epoxy Floor Paint achieves a verified surface resistance of 10⁶–10⁹ Ω — the electrostatic dissipative (ESD) classification defined under EN 61340-5-1 and ANSI/ESD S20.20. Conductivity is delivered by a conductive carbon additive integral to the epoxy film, not a surface treatment. The ESD performance does not wear away with foot traffic, fork-lift passes, or cleaning cycles.
Conductivity is built into the epoxy film through a precisely loaded conductive carbon additive — not applied as a topical treatment. No periodic retreatment schedule, no risk of uneven ESD degradation. For facilities that have seen topical anti-static treatments lose effectiveness after cleaning, this is the structural difference that matters in a conductive epoxy floor implementation. The resistance remains stable across the coating's full service life.
As an EN 61340-5-1 certified supplier, we provide: CE certificate, EN 61340-5-1 test reports, COA, TDS, and MSDS. Selecting ESD coatings without reviewing actual test reports is a common procurement error. Process verification — not brand trust — is the reliable path to compliance confidence before facility commissioning.
This product is designed for use with copper grounding strips and earth bonding systems. A complete ESD floor system — primer, anti-static topcoat, and grounding specification — is available. A conductive epoxy floor implementation without a properly designed grounding path will not protect against ESD events regardless of coating resistance. The floor coating and the grounding system must work together.
All 16 HC51 series colours — Light Grey, Medium Grey, Dark Grey, Beige, Light Green, Blue-Grey, Racing Red, and more — are available at the same surface resistance specification. Colour-coded zone layouts are a standard requirement in semiconductor cleanroom flooring and electronics manufacturing facilities; anti-static performance does not restrict colour selection in this product line.
Compressive strength ≥ 60 MPa and tensile bond strength ≥ 1.5 MPa suit the mechanical demands of electronics manufacturing floors, data centre surrounds, and cleanroom environments with steady equipment movement and rigorous cleaning regimens.
| Parameter | Value |
|---|---|
| Product Type | Two-component anti-static epoxy floor paint |
| Mix Ratio (by weight) | Component A : Component B = 21 : 4 |
| Packaging | 25 kg/set (A: 21 kg + B: 4 kg) |
| Surface Resistance | 10⁶–10⁹ Ω (EN 61340-5-1 electrostatic dissipative range) |
| Compressive Strength | ≥ 60 MPa |
| Tensile Bond Strength | ≥ 1.5 MPa |
| Dry Film Thickness | 0.2–0.4 mm per coat (2 coats) |
| Application Rate | 0.2–0.3 kg/m² per coat |
| Standard Colours | 16 colours (HC51 series) |
| MOQ | 1 tonne |
| Certifications | CE, ISO 9001, ISO 14001 |
Any serious ESD floor paint comparison starts with the resistance specification. EN 61340-5-1 defines three zones: conductive (<10⁶ Ω), electrostatic dissipative (10⁶–10⁹ Ω), and insulative (>10¹² Ω). Facilities handling sensitive electronic components or operating semiconductor cleanroom flooring need the dissipative range — verified by test report, not assumed from a supplier brochure.
Specifying semiconductor cleanroom flooring for a wafer fabrication bay means the coating must meet ANSI/ESD S20.20, provide a consistent dissipative surface, and integrate with the facility grounding plan. Anti-static epoxy ROI case studies show that facilities choosing certified, integral-conductivity coatings avoided re-coating cycles that inflate total floor ownership cost over five years — the comparison is not just about upfront price per square metre. Facilities that invest in compliant documentation upfront also avoid costly re-certification during periodic ESD audits.
Raised floors and concrete subfloors both present ESD risks during hardware installation and maintenance. A conductive epoxy floor implementation in a data centre should achieve 10⁶–10⁹ Ω under site ambient conditions — temperature and humidity both affect measured resistance. If your facility operates at low relative humidity (below 30%), verifying resistance under those specific conditions is important. Coatings with integral carbon loading maintain more consistent resistance across humidity variation than topical treatments.
Pharmaceutical cleanroom floors require both contamination control and ESD protection simultaneously. The smooth solid-colour finish supports standard cleaning protocols; integral anti-static performance reduces the secondary contamination risk associated with topical anti-static sprays applied during production. For precision instrument assembly workshops, a permanent dissipative surface that does not require additional chemical treatments during production operations simplifies the maintenance schedule.


Shandong Dingtai Waterproof Technology Co., Ltd. is a leading manufacturer based in China' s largest waterproof material production hub-Taitou Industrial Park.As a company with independent import-export rights,we have successfully supplied products across global markets countriesand regions such as North America, Southeast Asia, South America, Africa,Europe and the Middle East. Our commitment to superior quality andreliable service has earned us a strong international reputation andgrowing market presence.

Q1: Why choose us ?
A: We are professional manufacturer, and we can provide the best product ,competitive priceand excellent service.
Q2: Do you provide sample ?ls it free or extra ?
A: Yes,we can provide free sample for quality inspection.According to the regulations of our company , you should assume the freight ,and we will return the freight if you place the order.
Q3: How about the delivery time ?
A: 7-15 days after receive the deposit or LC at sight
Q4: How does your factory do regarding quality control?
A: Quality is priority,. We always attach great importance to quality control from the very beginning to the end. We have a professional QA/QC team to ensure the quality.
Q5: Do you accept OEM or ODM order?
A: Yes, we accept both OEM and ODM for customers.
Q6: What are your terms of delivery?
A: We can accept EXW, FOB, ClF, etc. You can choose one which is the most convenient for you.
Q7: What is the payment way?
A: TT, L/C at sight, West Union,Online Bank Payment.
Q8: Are you trading company or manufacturer?
A: We are manufacturer.So we have a lower price than trading company.
Anti-static epoxy floor paint, 25kg set (A 21kg + B 4kg). Surface resistance 10⁶–10⁹ Ω — ESD compliant floor for electronics manufacturing, data centres, and precision instrument facilities. 16 colours. MOQ 1 ton. CE certified.