bitumen-based-liquid-waterproof-membrane--cold-applied-20kg-underground--foundation, bitumen-based-liquid-waterproof-membrane--cold-applied-20kg-underground--foundation, /liquid-membrane
Inquiry
bitumen-based-liquid-waterproof-membrane--cold-applied-20kg-underground--foundation, bitumen-based-liquid-waterproof-membrane--cold-applied-20kg-underground--foundation, 
Inquiry

Bitumen-Based Liquid Waterproof Membrane – Cold Applied, 20kg, Underground & Foundation

Bitumen-based cold-applied liquid waterproof membrane, 20kg. No heating required — brush or spray applied for underground foundations, piling, basement walls, and buried pipe waterproofing. High hydrostatic resistance. MOQ 1 ton. CE certified.

Request a Quote
  • Overview

Overview

Cold-Applied Bitumen Membrane – Underground Foundation Waterproofing

This cold-applied bitumen membrane is made from high-quality modified bitumen emulsion, applied by brush, roller, or airless spray to concrete, masonry, and metal substrates without open flame or heating equipment. Once cured, it forms a tenacious bituminous film that delivers robust hydrostatic resistance waterproofing for below-grade structures, buried infrastructure, and foundation elements. The liquid format eliminates open-flame safety risks of hot-applied bitumen systems while ensuring complete coverage of irregular geometries — weld seams, bolt holes, pile shoulders, and re-entrant corners that sheet membranes are challenging to seal reliably.

Bitumen-Based Liquid Waterproof Membrane – Cold Applied, 20kg, Underground & Foundation manufacture

Key Features

No Heating or Open Flame Required

The cold-applied bitumen membrane removes open flames and hot-kettle equipment from the worksite. For underground foundation projects in confined spaces or fire-restricted sites, this reduces both compliance burden and labour complexity. One clarification: cold-applied does not mean reduced performance — the cured film achieves equivalent hydrostatic resistance waterproofing to heat-applied alternatives, given proper substrate preparation.

Liquid-Applied Coverage for Complex Substrates

A liquid cold-applied bitumen membrane conforms to substrate geometry by definition, substantially reducing bridging failure risk at corners, pile cap transitions, pipe penetrations, and tie-rod holes. Sheet membranes require extensive detailing at these points and carry inherent quality-control risk. The liquid application approach is therefore the preferred choice for below-grade structures with complex geometry or multiple penetrations.

High Hydrostatic Resistance

Sustained water pressure resistance ≥ 0.4 MPa — approximately 40 metres of water column — meets the design requirements of most commercial basement walls and buried infrastructure in moderate to high groundwater environments. The ≥ 0.6 MPa tensile strength ensures the film retains structural integrity under sustained hydrostatic load, not only during short-term testing. For deep basements or submerged structures, verify project-specific design pressure against this specification before selection.

Combined Waterproofing and Corrosion Protection

Steel piling, buried pipework, and metal structures in aggressive soils benefit from the dual function of this bituminous film: simultaneous waterproofing and anti-corrosion protection. In soils with elevated chloride content, sulfate exposure, or pH extremes, integrating both functions into a single cold-applied coating reduces system complexity and eliminates the coordination cost between separate protective-coating and waterproofing trades.

CE Certified — Full Documentation Package

CE certification and ISO 14001 environmental management system certification support compliance for European and international project specifications. As a CE certified waterproofing supplier, Shandong Dingtai provides a complete documentation package: CE declaration, COA, TDS, MSDS, and SDS. For procurement teams preparing submissions for LEED, BREEAM, or government infrastructure tenders, this significantly reduces the documentation preparation burden for project approvals.

Technical Specifications

Parameter Value
Product Type Bitumen-based cold-applied liquid waterproof membrane
Solid Content ≥ 55%
Elongation at Break ≥ 200%
Tensile Strength ≥ 0.6 MPa
Water Tightness Pass at 0.4 MPa, 30 minutes
Application Rate 1.0–2.0 kg/m² per coat
Packaging 20 kg/bucket
MOQ 1 ton
Certifications CE, ISO 14001

The water tightness pass at 0.4 MPa for 30 minutes confirms suitability for high-groundwater basement walls and buried infrastructure. Combined with ≥ 200% elongation at break, the membrane accommodates minor substrate movement without cracking — a critical requirement in underground foundation applications where concrete settlement is unavoidable over time.

Application Scenarios

Underground Basement Walls and Foundation Waterproofing

The primary application: external faces of concrete foundation walls in groundwater-affected sites, applied before backfill to form a continuous impermeable layer. The liquid format allows seamless extension over slab-to-wall junctions, kicker details, and surface irregularities. In underground foundation waterproofing, substrate preparation quality is the single biggest performance variable — clean, sound, dry concrete at 1.0–2.0 kg/m² per coat is the baseline for achieving the rated water tightness. Skipping surface cleaning or applying over wet substrate compromises adhesion regardless of membrane specification.

Steel and Concrete Piling Protection

Steel sheet piles, H-piles, and bored piles driven through chemically aggressive soils benefit from bituminous coating applied to pile shafts and splice locations before installation. The cold-applied bitumen membrane is suited to cylindrical pile shafts and irregular pile heads where sheet-applied coatings are impractical. For contractors with tight installation programmes, the cold-applied system eliminates the setup time and fire safety management required for hot-applied bitumen on large piling contracts.

Buried Pipes, Culverts, and Retaining Walls

Buried infrastructure — stormwater culverts, retaining wall back-faces, service ducts, and below-grade pipe chases — shares one critical characteristic: post-installation remediation access is difficult or impossible. The ability to spray-apply at 1.0–2.0 kg/m² makes this cold-applied bitumen membrane practical for large retaining wall areas, while brush application handles confined culvert interiors. As an underground foundation waterproofing solution, it is rated for the sustained moisture contact, variable soil chemistry, and zero-access conditions these elements face throughout their service life.

waterproof-coating-scene.png

Why Choose Us

  • 20 years of bitumen-based liquid membrane manufacturing with proven underground project supply
  • ISO 9001 & ISO 14001 certified; 11,000 tons annual production capacity
  • Bitumen content, modifier type, and solid content customisable on request
  • MOQ 1 ton; OEM/private label with custom 20kg packaging
  • Full documentation: CE, COA, TDS, MSDS, SDS
  • Competitive factory-direct pricing for bulk underground and infrastructure project supply

details (1).png

About Company

Shandong Dingtai Waterproof Technology Co., Ltd. is a leading manufacturer based in China' s largest waterproof material production hub-Taitou Industrial Park.As a company with independent import-export rights,we have successfully supplied products across global markets countriesand regions such as North America, Southeast Asia, South America, Africa,Europe and the Middle East. Our commitment to superior quality andreliable service has earned us a strong international reputation andgrowing market presence.

details (2).png

details (3).png

Frequently Asked Questions

Q1: Why choose us ?

A: We are professional manufacturer, and we can provide the best product ,competitive priceand excellent service.

Q2: Do you provide sample ?ls it free or extra ?

A: Yes,we can provide free sample for quality inspection.According to the regulations of our company , you should assume the freight ,and we will return the freight if you place the order.

Q3: How about the delivery time ?

A: 7-15 days after receive the deposit or LC at sight

Q4: How does your factory do regarding quality control?

A: Quality is priority,. We always attach great importance to quality control from the very beginning to the end. We have a professional QA/QC team to ensure the quality.

Q5: Do you accept OEM or ODM order?

A: Yes, we accept both OEM and ODM for customers.

Q6: What are your terms of delivery?

A: We can accept EXW, FOB, ClF, etc. You can choose one which is the most convenient for you.

Q7: What is the payment way?

A: TT, L/C at sight, West Union,Online Bank Payment.

Q8: Are you trading company or manufacturer?

A: We are manufacturer.So we have a lower price than trading company.

Bitumen-Based Liquid Waterproof Membrane – Cold Applied, 20kg, Underground & Foundation

Bitumen-based cold-applied liquid waterproof membrane, 20kg. No heating required — brush or spray applied for underground foundations, piling, basement walls, and buried pipe waterproofing. High hydrostatic resistance. MOQ 1 ton. CE certified.

Request a Quote

You May Also Like

bitumen based liquid waterproof membrane  cold applied 20kg underground  foundation-1

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000